Fantech
Site Search
What's New FAQ Company Info Table of Contents Contact Us Rep Login Dist Login
Improving Indoor Air Quality Through Better Ventilation
ALL PDF
Inline Duct Fans
Dryer Booster Fans
Exterior Fans
Exhaust Fans
Axial Fans
Radon Fans
Whole House HEPA Filtration
Heat Recovery Ventilators
Energy Recovery Ventilators
Air Curtains
Grilles & Dampers
Accessories









Bath Indoor Air Quality Kitchen Dryer Boosting Light Commercial
 



Heat & Energy Recovery Ventilators


Fantech Provides Ventilation Solutions To Improve Indoor Air Quality

Indoor air quality problems have soared since the late 1970’s when construction technology succeeded in developing energy efficient "tight" houses. Pollutants inside houses, which once escaped through cracks around windows and doors, are now trapped inside creating an indoor environment that is often 2 to 5 times more polluted than outside. Pet dander, mold spores, dust mites, allergens, tobacco smoke and other pollutants add up to poor indoor air quality.

Fantech's new line of IAQ Products can help you solve these problems through better ventilation. Choose from a complete line of Heat Recovery and Energy Recovery Ventilators to bring fresh outside air into the house while expelling stale polluted air.

Discover the benefits of Fantech's new Whole House HEPA Filtration unit that can be easily installed on a furnace/air handler or used as an independent system to clean the air in an average size house once each hour.

Each Fantech IAQ Product is designed using state-of-the-art technology and quality components to give you long life and dependable operation. We guarantee it.

Selecting The Right Unit

The climate conditions where you live will determine whether you need a Heat Recovery Ventilator or an Energy Recovery Ventilator.

HRV's are usually recommended for colder climates with longer heating seasons. ERV's are used for warmer more humid climates with long cooling seasons. Use map for reference.

HRV Required
HRV Recommended
HRV Recommended
HRV or ERV* w/Defrost
Recommended
ERV* Required

*Note: When installing ERVs (in ERV areas according to the map), and the outdoor temperature falls below 23°F (-5°C) for more than 2 consecutive days, it is recommended that a defrost option be installed on the equipment.

Sizing For Your Residential Needs

HRVs/ERVs are typically sized to ventilate the whole house at a minimum of .35 air changes per hour. To calculate, simply take the square footage of the house (including basement) and multiply by the height of the ceiling to get cubic volume. Then, divide by 60 and multiply by .35.


* Always consult your local code for sizing requirements in your area.

THE HEART OF THE SYSTEM
Fantech HRVs (like the unit shown above) feature aluminum heat exchanger cores.
• In the heating season the core transfers heat from the outgoing, stale household air to preheat the incoming, fresh air.
•Cross-current sections, ensure the two air streams are always kept separate preventing the incoming fresh air from being contaminated by the outgoing stale air.
•During the air-conditioning season, the HRV reverses this process, removing some of the heat from the incoming air and transferring it to the outgoing air.
Fantech ERVs, which are ideal for warmer climates, use enthalpic cores to transfer both heat and moisture.
• Reduces indoor humidity in the air conditioning season.
• Maintains a comfortable humidity level in the home in the heating season.
ELECTRONIC CONTROL BOARD
Fantech Heat Recovery and Energy Recovery Units have been designed with new "high tech" electronic control boards. Features include:
• Accessory control contact allows the ventilator to connect to other equipment such as an existing forced air system to trigger the furnace blower motor to turn on and off on demand.
• A diagnostic LED
• Allows units to be easily operated from a remote Intellitek Multi-Function Wall Control.
CHOICE OF DEFROST MODE
The defrost mode activates when the temperature of incoming air is below 23°F (-5°C). Two types are available:
HRV without recirculation
• Features an automatic timed supply fan "shutdown".
HRV with recirculation uses a motorized damper to temporarily block incoming fresh air allowing the warm air from the house to circulate through the HRV.
• Maintains equal house pressure.
• Does not introduce household odors back into the home.
• Provides positive shutoff of supply air when unit is in standby mode.
FACTORY-BALANCED EBM MOTORS
Fantech HRVs and ERVs use superior German-manufactured, factory-balanced EBM motors.
• Vibration is reduced to a minimum providing quiet operation.
• Permanently lubricated sealed bearings guarantee long life and maintenance-free operation.
• Typical life expectancy of motor is in excess of 100,000 hours.
• 7 year warranty (limited).
SUPERIOR WARRANTIES
Fantech HRVs and ERVs carry the following superior warranties:
Motor: 7 year (Limited)
Core (Aluminum): Lifetime (Limited)
Core (Enthalpy): 5 year (Limited)
Other Components: 5 year (Limited)


To download more information or a submittal sheet on these products, simply click on the product name or picture.


Indoor Air Quality (1.56 Mb)
Compact Series Sell Sheet in PDF (107 kb)

Ventilators
Heat Recovery Ventilators SH Series
SHR Series Heat Recovery Ventilators (2.21 Mb)
SH704 (121 kb)
SHR 1504 (143 kb)
SHR 2004 (143 kb)
SHR 1505R (169 kb)
SHR 2005R (166 kb)
SHR 3005R (174 kb)
SHR 3205RD (181 kb)
Heat Recovery Ventilators VH Series
VHR Specification Sheet (690 kb)
VH704 (179 kb)
VHR704 (126 kb)
VHR 1404 (120 kb)
VHR 2004 (121 kb)
VHR 1405R (139 kb)
VHR 2005R (138 kb)
Energy Recovery Ventilators SE Series
SER Specification Sheet (335 kb)
SE704N (168 kb)
Heat Recovery Cores HRC Series
HRC(M) Series (97 kb)
HEPA Filtration Systems
DM 3000P (204 kb)
DM/CM Series (219 kb)

Air to Air Exchanger
AEV Series (248 kb)
Air Exchanger

Accessories, Additionals
New HRV/ERV Controls (277 kb)
CONTROLS (80 kb)
Multi-Function Wall Controls
CONTROLS (69 kb)
Controls & Accessories
Filtration (Inline Filtration) (128 kb)
Installation Instructions for Model FB6

More Information


Contact information

Technical - 1 (800) 565 - 3548
Commercial info - 1 (800) 487 - 9915 ext. 6024


Click here for our Light Commercial HRV/ERV Series


Fantech reserves the right to modify, at any time and without notice, any or all of its products' features, designs, components and specifications, to maintain their technological leadership position.

 


Product Lines | Ventilation Solutions | Rep Login | Dist Login